ShanghaiTech University Knowledge Management System
An Event-Driven Cardiac Monitoring System Based on a Low-Power Atrial-Fibrillation Detection ASIC With a Sensitivity of 92.5% | |
2024-03 | |
发表期刊 | IEEE SENSORS LETTERS (IF:2.2[JCR-2023],2.2[5-Year]) |
ISSN | 2475-1472 |
EISSN | 2475-1472 |
卷号 | 8期号:3 |
发表状态 | 已发表 |
DOI | 10.1109/LSENS.2024.3365731 |
摘要 | This letter presents an event-driven cardiac monitoring system for atrial-fibrillation (AF) detection through the co-design of a low-power application-specific integrated circuit (ASIC) and a back-end processor. Only when the AF abnormality is detected, the ASIC wakes up the processor from the standby mode, which transfers the AF episode from a front-end static random-access memory (SRAM) to the PC through a universal asynchronous receiver-transmitter (UART) interface. Afterward, the processor reenters the standby mode to reduce power consumption. An improved Pan and Tompkins algorithm is proposed, which achieves 49.7% power reduction compared with the conventional design. The R-peak detection and Kolmogorov-Smirnov-test (KS-test)-based AF-diagnosis algorithms are implemented as an ASIC in a 0.18-μm CMOS technology and achieve an AF-detection sensitivity of 92.45%. The system shows promise for realizing the next-generation implantable cardiac monitoring systems. © 2017 IEEE. |
关键词 | Sensor applications application-specific integrated circuit (ASIC) atrial-fibrillation (AF) cardiac monitoring system CMOS digital-signal processing electrocardiogram event-driven implantable medical device low-power Application specific integrated circuits CMOS integrated circuits Digital signal processing Diseases Electric power utilization Heart Interactive computer systems Patient monitoring Real time systems Static random access storage Atrial fibrillation Cardiac monitoring Cardiac monitoring system Event-driven Implantable medical devices Low Power Monitoring system Power demands Random access memory Real Time system |
URL | 查看原文 |
收录类别 | EI |
语种 | 英语 |
出版者 | Institute of Electrical and Electronics Engineers Inc. |
EI入藏号 | 20240815579799 |
EI主题词 | Electrocardiograms |
EI分类号 | 461.2 Biological Materials and Tissue Engineering ; 461.6 Medicine and Pharmacology ; 462.1 Biomedical Equipment, General ; 706.1 Electric Power Systems ; 714.2 Semiconductor Devices and Integrated Circuits ; 722.1 Data Storage, Equipment and Techniques ; 722.4 Digital Computers and Systems |
原始文献类型 | Journal article (JA) |
来源库 | IEEE |
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/352539 |
专题 | 信息科学与技术学院 信息科学与技术学院_硕士生 信息科学与技术学院_博士生 信息科学与技术学院_PI研究组_吕宏鸣组 |
通讯作者 | Lyu, Hongming |
作者单位 | 1.ShanghaiTech University, School of Information Science and Technology, Shanghai; 201210, China; 2.Chinese Academy of Sciences, Shanghai Institute of Microsystem and Information Technology, Shanghai; 200050, China; 3.University of Chinese Academy of Sciences, Beijing; 100049, China; 4.Shanghai Engineering Research Center of Energy Efficient and Custom Ai Ic, Shanghai; 201210, China |
第一作者单位 | 信息科学与技术学院 |
通讯作者单位 | 信息科学与技术学院 |
第一作者的第一单位 | 信息科学与技术学院 |
推荐引用方式 GB/T 7714 | Gu, Xinyue,Zhou, Kanjun,Lyu, Hongming. An Event-Driven Cardiac Monitoring System Based on a Low-Power Atrial-Fibrillation Detection ASIC With a Sensitivity of 92.5%[J]. IEEE SENSORS LETTERS,2024,8(3). |
APA | Gu, Xinyue,Zhou, Kanjun,&Lyu, Hongming.(2024).An Event-Driven Cardiac Monitoring System Based on a Low-Power Atrial-Fibrillation Detection ASIC With a Sensitivity of 92.5%.IEEE SENSORS LETTERS,8(3). |
MLA | Gu, Xinyue,et al."An Event-Driven Cardiac Monitoring System Based on a Low-Power Atrial-Fibrillation Detection ASIC With a Sensitivity of 92.5%".IEEE SENSORS LETTERS 8.3(2024). |
条目包含的文件 | ||||||
条目无相关文件。 |
修改评论