ShanghaiTech University Knowledge Management System
Re-calibration and nonuniform correction of thermal infrared band under cold space abnormal | |
2021-12-01 | |
发表期刊 | 红外与毫米波学报 (IF:0.6[JCR-2023],0.5[5-Year]) |
ISSN | 1001-9014 |
卷号 | 40期号:6页码:820-828 |
发表状态 | 已发表 |
DOI | 10.11972/j.issn.1001-9014.2021.06.016 |
摘要 | Chinese ocean color and temperature (COCTS) was interfered by the unknown radiation of cold space when the satellite of HY-1B was in orbit, which causes its nine-year data to be affected to varying degrees. Using data with less impact on the two poles as samples, the response repair model based on recalibration coefficients and the non-uniform correction model based on probability distribution were established to repair the earth target signal, and the repair results were compared and optimized. The accuracy and stability of model were verified. The final results show that under the condition of the cold space radiation benchmark affected, the response repair model combined with the probability distribution correction model can obviously repair the data effectively. © 2021, Science Press. All right reserved. |
关键词 | Orbits Probability distributions Remote sensing Cold space abnormal Correction models Infrared remote sensing Model-based OPC Nonuniform correction Ocean color Probability: distributions Recalibrations Repair models Thermal infrared bands |
收录类别 | EI ; 北大核心 ; SCI |
语种 | 中文 |
出版者 | Chinese Optical Society |
EI入藏号 | 20220811698069 |
EI主题词 | Repair |
EI分类号 | 913.5 Maintenance ; 922.1 Probability Theory |
原始文献类型 | Journal article (JA) |
引用统计 | 正在获取...
|
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/195013 |
专题 | 信息科学与技术学院_硕士生 信息科学与技术学院_特聘教授组_冯旗组 |
通讯作者 | Huang, Xiao-Xian; Feng, Qi |
作者单位 | 1.Key Laboratory of Infrared System Detection and Imaging Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai; 200083, China; 2.School of Information Science and Technology, ShanghaiTech University, Shanghai; 200083, China; 3.University of Chinese Academy of Sciences, Beijing; 100049, China |
第一作者单位 | 信息科学与技术学院 |
通讯作者单位 | 信息科学与技术学院 |
推荐引用方式 GB/T 7714 | Qu, Yang,Huang, Xiao-Xian,Feng, Qi. Re-calibration and nonuniform correction of thermal infrared band under cold space abnormal[J]. 红外与毫米波学报,2021,40(6):820-828. |
APA | Qu, Yang,Huang, Xiao-Xian,&Feng, Qi.(2021).Re-calibration and nonuniform correction of thermal infrared band under cold space abnormal.红外与毫米波学报,40(6),820-828. |
MLA | Qu, Yang,et al."Re-calibration and nonuniform correction of thermal infrared band under cold space abnormal".红外与毫米波学报 40.6(2021):820-828. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
修改评论