Influence of Spectral Peaks on EMG Parameter Estimation for Vibration-Exercise Analysis
2021-07-01
发表期刊IEEE SENSORS JOURNAL (IF:4.3[JCR-2023],4.2[5-Year])
ISSN1530-437X
EISSN1558-1748
卷号21期号:13页码:14141-14147
发表状态已发表
DOI10.1109/JSEN.2020.3038953
摘要

Many studies have proposed vibration exercise (VE) as a novel training modality for neuromuscular conditioning and rehabilitation. Surface electromyography (sEMG) is widely used for effective measurement of muscle activity. Unfortunately, sharp spectral peaks (SSP) are usually present in the EMG signals recorded during VE. The explanation of these sharp peaks, as muscle activity or motion artifacts, is controversial, complicating EMG parameter extraction for the analysis of VE. The present study aims to quantify the impact of these SSP on the estimation of EMG parameters irrespective of their nature. High-density sEMG was therefore recorded from the biceps brachii muscle during VE with different vibration amplitudes (VA) and frequencies (VF). The power around (+/- 0.5 Hz) VF and its first harmonic was calculated and normalized with the entire EMG power in order to obtain a relative power (P-R) of these peaks. In addition, before and after excluding the SSP, three EMG parameters, i.e., mean frequency (MF), root mean square (RMS), and conduction velocity (CV), were estimated and compared. Our results reveal an average P-R of 21.18 +/- 15.68 %. The relative difference in EMG RMS and MF are 12.2 +/- 3.8 % and 2.10 +/- 1.04 %, respectively. In addition, the impact of these peaks on the MF and RMS seems also to be affected by vibration conditions, such as VA and VF. However, the CV estimation seems not to be significantly influenced by these peaks, indicating these peaks to be primarily reflecting muscle activity and therefore should be included in VE EMG analysis.

关键词Electromyography Vibrations Muscles Force Training Sensors Harmonic analysis Conduction velocity electromyography mean frequency motion artifacts vibration exercise
URL查看原文
收录类别EI ; SCIE
语种英语
WOS研究方向Engineering ; Instruments & Instrumentation ; Physics
WOS类目Engineering, Electrical & Electronic ; Instruments & Instrumentation ; Physics, Applied
WOS记录号WOS:000668948200021
出版者IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
原始文献类型Article
来源库IEEE
引用统计
正在获取...
文献类型期刊论文
条目标识符https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/127733
专题信息科学与技术学院
信息科学与技术学院_博士生
信息科学与技术学院_PI研究组_徐林组
作者单位
1.School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2.Department of Electrical Engineering, Eindhoven University of Technology, AZ Eindhoven, The Netherlands
3.Department of Critical Care Medicine, Zhongshan Hospital Fudan University, Shanghai, China
第一作者单位信息科学与技术学院
第一作者的第一单位信息科学与技术学院
推荐引用方式
GB/T 7714
Yaodan Xu,Xi Long,Zhe Luo,et al. Influence of Spectral Peaks on EMG Parameter Estimation for Vibration-Exercise Analysis[J]. IEEE SENSORS JOURNAL,2021,21(13):14141-14147.
APA Yaodan Xu,Xi Long,Zhe Luo,Massimo Mischi,&Lin Xu.(2021).Influence of Spectral Peaks on EMG Parameter Estimation for Vibration-Exercise Analysis.IEEE SENSORS JOURNAL,21(13),14141-14147.
MLA Yaodan Xu,et al."Influence of Spectral Peaks on EMG Parameter Estimation for Vibration-Exercise Analysis".IEEE SENSORS JOURNAL 21.13(2021):14141-14147.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Yaodan Xu]的文章
[Xi Long]的文章
[Zhe Luo]的文章
百度学术
百度学术中相似的文章
[Yaodan Xu]的文章
[Xi Long]的文章
[Zhe Luo]的文章
必应学术
必应学术中相似的文章
[Yaodan Xu]的文章
[Xi Long]的文章
[Zhe Luo]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。