ShanghaiTech University Knowledge Management System
Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity | |
2025 | |
发表期刊 | SENSORS (IF:3.4[JCR-2023],3.7[5-Year]) |
ISSN | 1424-8220 |
EISSN | 1424-8220 |
卷号 | 25期号:2 |
发表状态 | 已发表 |
DOI | 10.3390/s25020433 |
摘要 | Optically pumped magnetometers (OPMs) functioning in the spin-exchange relaxation-free (SERF) regime have emerged as attractive options for measuring weak magnetic fields, owing to their portability and remarkable sensitivity. The operation of SERF-OPM critically relies on the ambient magnetic field; thus, a magnetic field compensation device is commonly employed to mitigate the ambient magnetic field to near zero. Nonetheless, the bias of the OPM may influence the compensation impact, a subject that remains unexamined. This paper introduced an innovative bias calibration technique for OPMs. The sensitivity of the OPM was altered by adjusting the cell temperature. The output of the OPM was then documented with varying sensitivity. It is assumed that the signal exhibits a linear correlation with the environmental magnetic field, and the statistical characteristics of the magnetic field are identical for both measurements, upon which the bias of the OPM is assessed. The bias was subsequently considered in the feedback magnetic field compensation mechanism. The results indicate that this technique might successfully reduce environmental magnetic fluctuations and enhance the sensitivity of the OPM. This technique measured the magnetic field produced by the human heart, confirming the viability of the ultra-weak biomagnetic field measurement approach. |
关键词 | OPM bias calibration biomagnetic field measurement magnetic field compensation |
URL | 查看原文 |
收录类别 | SCI ; EI |
语种 | 英语 |
资助项目 | null[2022YFF1202800] |
WOS研究方向 | Chemistry ; Engineering ; Instruments & Instrumentation |
WOS类目 | Chemistry, Analytical ; Engineering, Electrical & Electronic ; Instruments & Instrumentation |
WOS记录号 | WOS:001405407600001 |
出版者 | MDPI |
EI入藏号 | 20250417755137 |
EI主题词 | Biomagnetism |
EI分类号 | 103 Biology ; 701.1 Electricity: Basic Concepts and Phenomena ; 701.2 Magnetism: Basic Concepts and Phenomena ; 941.3 Electric Variables Measurements ; 941.4 Magnetic Variables Measurements ; 941.5 Mechanical Variables Measurements���� ; 942.1.5 Magnetic Instruments ; 942.1.7 Special Purpose Instruments |
原始文献类型 | Journal article (JA) |
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/483952 |
专题 | 信息科学与技术学院 信息科学与技术学院_PI研究组_叶朝锋组 信息科学与技术学院_硕士生 信息科学与技术学院_博士生 |
通讯作者 | Ye, Chaofeng; Sun, Limin |
作者单位 | 1.Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China 2.ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China |
第一作者单位 | 信息科学与技术学院 |
通讯作者单位 | 信息科学与技术学院 |
推荐引用方式 GB/T 7714 | Chen, Jieya,Ye, Chaofeng,Hou, Xingshen,et al. Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity[J]. SENSORS,2025,25(2). |
APA | Chen, Jieya,Ye, Chaofeng,Hou, Xingshen,Niu, Yaqiong,&Sun, Limin.(2025).Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity.SENSORS,25(2). |
MLA | Chen, Jieya,et al."Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity".SENSORS 25.2(2025). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
修改评论
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。