Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity
2025
发表期刊SENSORS (IF:3.4[JCR-2023],3.7[5-Year])
ISSN1424-8220
EISSN1424-8220
卷号25期号:2
发表状态已发表
DOI10.3390/s25020433
摘要

Optically pumped magnetometers (OPMs) functioning in the spin-exchange relaxation-free (SERF) regime have emerged as attractive options for measuring weak magnetic fields, owing to their portability and remarkable sensitivity. The operation of SERF-OPM critically relies on the ambient magnetic field; thus, a magnetic field compensation device is commonly employed to mitigate the ambient magnetic field to near zero. Nonetheless, the bias of the OPM may influence the compensation impact, a subject that remains unexamined. This paper introduced an innovative bias calibration technique for OPMs. The sensitivity of the OPM was altered by adjusting the cell temperature. The output of the OPM was then documented with varying sensitivity. It is assumed that the signal exhibits a linear correlation with the environmental magnetic field, and the statistical characteristics of the magnetic field are identical for both measurements, upon which the bias of the OPM is assessed. The bias was subsequently considered in the feedback magnetic field compensation mechanism. The results indicate that this technique might successfully reduce environmental magnetic fluctuations and enhance the sensitivity of the OPM. This technique measured the magnetic field produced by the human heart, confirming the viability of the ultra-weak biomagnetic field measurement approach.

关键词OPM bias calibration biomagnetic field measurement magnetic field compensation
URL查看原文
收录类别SCI ; EI
语种英语
资助项目null[2022YFF1202800]
WOS研究方向Chemistry ; Engineering ; Instruments & Instrumentation
WOS类目Chemistry, Analytical ; Engineering, Electrical & Electronic ; Instruments & Instrumentation
WOS记录号WOS:001405407600001
出版者MDPI
EI入藏号20250417755137
EI主题词Biomagnetism
EI分类号103 Biology ; 701.1 Electricity: Basic Concepts and Phenomena ; 701.2 Magnetism: Basic Concepts and Phenomena ; 941.3 Electric Variables Measurements ; 941.4 Magnetic Variables Measurements ; 941.5 Mechanical Variables Measurements���� ; 942.1.5 Magnetic Instruments ; 942.1.7 Special Purpose Instruments
原始文献类型Journal article (JA)
文献类型期刊论文
条目标识符https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/483952
专题信息科学与技术学院
信息科学与技术学院_PI研究组_叶朝锋组
信息科学与技术学院_硕士生
信息科学与技术学院_博士生
通讯作者Ye, Chaofeng; Sun, Limin
作者单位
1.Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
2.ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
第一作者单位信息科学与技术学院
通讯作者单位信息科学与技术学院
推荐引用方式
GB/T 7714
Chen, Jieya,Ye, Chaofeng,Hou, Xingshen,et al. Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity[J]. SENSORS,2025,25(2).
APA Chen, Jieya,Ye, Chaofeng,Hou, Xingshen,Niu, Yaqiong,&Sun, Limin.(2025).Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity.SENSORS,25(2).
MLA Chen, Jieya,et al."Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity".SENSORS 25.2(2025).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Chen, Jieya]的文章
[Ye, Chaofeng]的文章
[Hou, Xingshen]的文章
百度学术
百度学术中相似的文章
[Chen, Jieya]的文章
[Ye, Chaofeng]的文章
[Hou, Xingshen]的文章
必应学术
必应学术中相似的文章
[Chen, Jieya]的文章
[Ye, Chaofeng]的文章
[Hou, Xingshen]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。