Noise removal in single-lead capacitive ECG with adaptive filtering and singular value decomposition | |
2024 | |
发表期刊 | IEEE ACCESS (IF:3.4[JCR-2023],3.7[5-Year]) |
ISSN | 2169-3536 |
EISSN | 2169-3536 |
卷号 | PP期号:99 |
发表状态 | 已发表 |
DOI | 10.1109/ACCESS.2024.3478779 |
摘要 | Capacitive electrodes have been proposed to measure the electrocardiography (ECG) without direct skin contact. Unfortunately, capacitive ECG (cECG) measurements are very sensitive to various types of noise, and are therefore limited for heart-rate monitoring. The aim of the present study is to explore the feasibility of a cECG system with dedicated denoising algorithms for clinical diagnosis. We conducted real cECG measurements on 12 healthy subjects while simultaneously obtaining traditional wet ECG measurements as references. An adaptive canceller and an innovative singular value decomposition (SVD) algorithm were applied to single-lead cECG for noise reduction. The correlation coefficients (CCs) between the processed cECG and the wet ECG were computed with and without the QRS complex as performance metrics. In addition, several clinical parameters were annotated from the detailed waves of both ECG signals by a medical expert and then compared. The results demonstrate high CCs between the cECG and wet ECG for both conditions. Furthermore, the clinical parameters identified from both signals are quite similar. These findings indicate the potential of cECG for morphological analysis in clinical settings. |
关键词 | Adaptive filters Electrocardiography Empirical mode decomposition Wiener filtering Capacitive electrocardiography Capacitive electrodes Clinical parameters Correlation coefficient Heart-rate monitoring Morphological analysis Noises removal Singular values Skin contact Value decomposition |
URL | 查看原文 |
收录类别 | EI |
语种 | 英语 |
出版者 | Institute of Electrical and Electronics Engineers Inc. |
EI入藏号 | 20244417273997 |
EI主题词 | Adaptive filtering |
EI分类号 | 102.1 ; 1106.3 ; 703.2 Electric Filters ; 709 Electrical Engineering, General ; 716.1 Information Theory and Signal Processing |
原始文献类型 | Article in Press |
来源库 | IEEE |
引用统计 | 正在获取...
|
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/433543 |
专题 | 信息科学与技术学院 信息科学与技术学院_硕士生 |
作者单位 | 1.School of Information Science and Technology, ShanghaiTech University, Shanghai, China 2.Concordia International School Shanghai, Shanghai, China 3.Department of Cardiology, first affiliated hospital with Nanjing Medical University, Nanjing, Jiangsu, China |
第一作者单位 | 信息科学与技术学院 |
第一作者的第一单位 | 信息科学与技术学院 |
推荐引用方式 GB/T 7714 | Kaichen Wang,Cathy Tu,Chi Man Qian,et al. Noise removal in single-lead capacitive ECG with adaptive filtering and singular value decomposition[J]. IEEE ACCESS,2024,PP(99). |
APA | Kaichen Wang.,Cathy Tu.,Chi Man Qian.,Runwei Lin.,David Doyle.,...&Junhong Wang.(2024).Noise removal in single-lead capacitive ECG with adaptive filtering and singular value decomposition.IEEE ACCESS,PP(99). |
MLA | Kaichen Wang,et al."Noise removal in single-lead capacitive ECG with adaptive filtering and singular value decomposition".IEEE ACCESS PP.99(2024). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
修改评论
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。