ShanghaiTech University Knowledge Management System
An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens | |
2023 | |
发表期刊 | ANALYST (IF:3.6[JCR-2023],3.7[5-Year]) |
ISSN | 0003-2654 |
EISSN | 1364-5528 |
卷号 | 148期号:12页码:2758-2766 |
发表状态 | 已发表 |
DOI | 10.1039/d3an00271c |
摘要 | This paper introduces an enclosed microfluidic chip that integrates sample preparation and the chamber-based digital polymerase chain reaction (cdPCR). The sample preparation of the chip includes nucleic acid extraction and purification based on magnetic beads, which adsorb nucleic acids by moving around the reaction chambers to complete the reactions including lysis, washing, and elution. The cdPCR area of the chip consists of tens of thousands of regularly arranged microchambers. After the sample preparation processes are completed, the purified nucleic acid can be directly introduced into the microchambers for amplification and detection on the chip. The nucleic acid extraction performance and digital quantification performance of the system were examined using synthetic SARS-CoV-2 plasmid templates at concentrations ranging from 101-105 copies per μL. Further on, a simulated clinical sample was used to test the system, and the integrated chip was able to accurately detect SARS-CoV-2 virus particle samples doped with interference (saliva) with a detection limit of 10 copies per μL. This integrated system could provide a promising tool for point-of-care testing of pathogenic infections. © 2023 The Royal Society of Chemistry |
关键词 | Biomolecules Coronavirus Diseases Extraction Microfluidic chips Microfluidics Purification Acid purification Extraction and purifications Integrated microfluidic chips Magnetic beads Micro-chambers Microfluidic-chips Nucleic acids extractions Performance Reaction chambers Sample preparation |
收录类别 | EI |
语种 | 英语 |
出版者 | Royal Society of Chemistry |
EI入藏号 | 20232214171286 |
EI主题词 | Polymerase chain reaction |
EI分类号 | 461.6 Medicine and Pharmacology ; 461.9 Biology ; 632.5.1 Microfluidics ; 801.2 Biochemistry ; 802.3 Chemical Operations |
原始文献类型 | Article in Press |
引用统计 | 正在获取...
|
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/306490 |
专题 | 信息科学与技术学院 信息科学与技术学院_硕士生 |
通讯作者 | Jia, Chunping; Zhao, Jianlong; Feng, Shilun |
作者单位 | 1.Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, China; 2.School of Life Sciences, Shanghai Normal University, China; 3.School of Information Science and Technology, ShanghaiTech University, China; 4.Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, China; 5.Xiangfu Laboratory, Zhejiang, Jiaxing; 314102, China |
推荐引用方式 GB/T 7714 | Huang, Yaru,Gao, Zehang,Ma, Cong,et al. An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens[J]. ANALYST,2023,148(12):2758-2766. |
APA | Huang, Yaru.,Gao, Zehang.,Ma, Cong.,Sun, Yimeng.,Huang, Yuhang.,...&Feng, Shilun.(2023).An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens.ANALYST,148(12),2758-2766. |
MLA | Huang, Yaru,et al."An integrated microfluidic chip for nucleic acid extraction and continued cdPCR detection of pathogens".ANALYST 148.12(2023):2758-2766. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
修改评论
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。