| |||||||
ShanghaiTech University Knowledge Management System
Effects of Working Fluids on Operating Characteristics of the Cryogenic Loop Heat Pipe in 180~230 K | |
2020-11-20 | |
发表期刊 | 工程科学与技术 |
ISSN | 2096-3246 |
卷号 | 52期号:6页码:190-198 |
发表状态 | 已发表 |
DOI | 10.15961/j.jsuese.201900820 |
摘要 | The cryogenic loop heat pipe is a high-efficiency two-phase heat transfer device that is commonly used in space thermal control systems. In order to investigate the suitable working fluids for LHP in 180~230 K for space exploration applications, the effects of working fluids on the operating characteristics including start-ups, responses of the operating temperatures to the heat load rise, and thermal resistances of the LHP at steady states were researched by employing ethylene, ethane and propylene as fluid candidates. The experimental results and analysis showed that by controlling the temperatures of the evaporator and the compensation chamber at least 10 K below the critical temperatures of the fluids, the LHP achieved successful start-up with heat loads of 5 W. With approximate evaporator temperatures before the start-up, the start-up temperature rise were both within 2 K for the ethane and propylene charged LHP, the start-up time of the ethane charged LHP was less than that of the propylene charged one, and the latent heat and liquid viscosity of working fluids were largely responsible for the differences in the start-up time. The effect of working fluids on the responses of the LHP operating temperatures to the heat load rise was not obvious. The evaporator temperatures decreased and then increased with the rising heat load. The lowest evaporator temperatures occurred with heat loads of 20~30 W, and the time for the LHP to reach the new steady-state decreased with the heat load rise. The pressure drops of the working fluids in the external loop accounted for the significant differences among the heat transfer thermal resistances of the LHP at steady states, and the vapor phase pressure drops took the majority part of the external pressure drops. The smaller vapor pressure drop led to the smaller thermal resistance. The vapor pressure drops of the ethylene charged LHP were less than that of the ethane and then the propylene charged LHP with the same heat loads, and the vapor pressure drops for all three fluids decreased with the increasing temperature. Correspondingly, the thermal resistances of the ethylene charged LHP were less than that of the ethane and then the propylene charged one, all thermal resistances decreased with the rising temperature. The smallest thermal resistance obtained experimentally was 0.21 K/W. Copyright ©2020 Advanced Engineering Sciences. All rights reserved. |
关键词 | Ethylene Evaporators Space research Vapor pressure Drops Thermal load Ethane Pressure drop Propylene Heat resistance Heat transfer Hydrostatic pressure Critical temperatures Cryogenic loop heat pipes Evaporator temperature Heat transfer thermal resistances Increasing temperatures Operating characteristics Thermal control systems Two-phase heat transfer |
收录类别 | EI ; CSCD ; 北大核心 |
语种 | 中文 |
出版者 | Sichuan University |
EI入藏号 | 20204809554374 |
EI主题词 | Heat pipes |
EI分类号 | 619.1 Pipe, Piping and Pipelines ; 631.1.1 Liquid Dynamics ; 641.1 Thermodynamics ; 641.2 Heat Transfer ; 656.2 Space Research ; 802.1 Chemical Plants and Equipment ; 804.1 Organic Compounds |
原始文献类型 | Journal article (JA) |
文献类型 | 期刊论文 |
条目标识符 | https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/251737 |
专题 | 信息科学与技术学院_特聘教授组_吴亦农组 |
作者单位 | 1.Shanghai Inst. of Technol. Phy., Chinese Academy of Sciences, Shanghai; 200083, China; 2.School of Info. Sci. and Technol., Shanghai Technol. Univ., Shanghai; 201210, China; 3.Univ. of Chinese Academy of Sciences, Beijing; 100049, China |
推荐引用方式 GB/T 7714 | Liu, Cheng,Xie, Rongjian,Wu, Yinong. Effects of Working Fluids on Operating Characteristics of the Cryogenic Loop Heat Pipe in 180~230 K[J]. 工程科学与技术,2020,52(6):190-198. |
APA | Liu, Cheng,Xie, Rongjian,&Wu, Yinong.(2020).Effects of Working Fluids on Operating Characteristics of the Cryogenic Loop Heat Pipe in 180~230 K.工程科学与技术,52(6),190-198. |
MLA | Liu, Cheng,et al."Effects of Working Fluids on Operating Characteristics of the Cryogenic Loop Heat Pipe in 180~230 K".工程科学与技术 52.6(2020):190-198. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
修改评论
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。