消息
×
loading..
Optimization of the Contrast Agent Injection Protocol for Carotid Artery Dynamic Contrast-Enhanced Magnetic Resonance Imaging
2022-11
发表期刊JOURNAL OF MAGNETIC RESONANCE IMAGING (IF:3.3[JCR-2023],4.4[5-Year])
ISSN1053-1807
EISSN1522-2586
发表状态已发表
DOI10.1002/jmri.28175
摘要

Background The injection protocol used in previous carotid artery dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) studies varied. Purpose To investigate the effect of contrast injection protocol and optimize this protocol for carotid artery DCE-MRI. Study Type Prospective. Subjects Digital phantom and seven patients with carotid atherosclerosis. Field Strength/Sequence 3 T, spoiled gradient recalled echo sequence. Assessment Different injection doses (0.01-0.3 mmol/kg) and effective injection rates (0.01-1 mmol/sec) were tested using a digital carotid plaque phantom considering the contrast pharmacokinetics, DCE-MRI imaging, contrast variation and flow-related imaging artifacts, random time delay between the contrast injection and image acquisition, and pharmacokinetic analysis process. For each injection protocol, combining the root mean square relative error (RMSRE) of the measured Ktrans and vP maps within the adventitial vasa vasorum from 10 tested time delays by the root mean square produced RMSREoverall-vv which was used to measure the overall accuracy of the pharmacokinetic parameters. In vivo validation was performed on seven patients with carotid atherosclerosis by imaging them twice using the traditional commonly used protocol and the recommended protocol found by simulation. Statistical Test Student's t-test, chi-square test, and paired t-test, P < 0.05 was considered statistically significant. Results A low region of RMSREoverall-vv with the combination of medium injection dose and low effective injection rate was found. The protocol with injection dose of 0.07 mmol/kg and effective injection rate of 0.06 mmol/sec achieved the minimal RMSREoverall-vv (4.29%), thus was recommended, which showed more accurate arterial input function. Coinciding with the simulation results, this recommended protocol in in vivo experiments produced significantly fewer image artifacts, lower Ktrans and vP (P all <0.05) than traditional protocol which overestimated these parameters in simulation. Data Conclusion The contrast injection protocol influenced the accuracy of the pharmacokinetics parameter estimation in carotid artery DCE-MRI. The injection protocol with injection dose of 0.07 mmol/kg and effective injection rate of 0.06 mmol/sec was recommended. Level of Evidence 2 Technical Efficacy Stage 1

关键词dynamic contrast-enhanced carotid atherosclerotic plaque permeability injection dose effective injection rate
URL查看原文
收录类别SCI ; SCIE
语种英语
资助项目Beijing Municipal Natural Science Foundation[Z190024] ; National Natural Science Foundation of China[81930119,81371540,81571667] ; Natural Science Foundation of Hubei Province of China[2021CFB442]
WOS研究方向Radiology, Nuclear Medicine & Medical Imaging
WOS类目Radiology, Nuclear Medicine & Medical Imaging
WOS记录号WOS:000772483900001
出版者WILEY
引用统计
正在获取...
文献类型期刊论文
条目标识符https://kms.shanghaitech.edu.cn/handle/2MSLDSTB/169252
专题生物医学工程学院
生物医学工程学院_PI研究组_齐海坤组
通讯作者Wang, Jing; Chen, Huijun
作者单位
1.Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Hubei, Peoples R China
2.Hubei Prov Key Lab Mol Imaging, Wuhan 430022, Hubei, Peoples R China
3.Tsinghua Univ, Ctr Biomed Imaging Res, Dept Biomed Engn, Sch Med, Beijing 100084, Peoples R China
4.Philips Healthcare, Beijing, Peoples R China
5.ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
推荐引用方式
GB/T 7714
Wang, Yajie,Liu, Xiaoming,Wang, Yishi,et al. Optimization of the Contrast Agent Injection Protocol for Carotid Artery Dynamic Contrast-Enhanced Magnetic Resonance Imaging[J]. JOURNAL OF MAGNETIC RESONANCE IMAGING,2022.
APA Wang, Yajie.,Liu, Xiaoming.,Wang, Yishi.,Qi, Haikun.,Liu, Xian.,...&Chen, Huijun.(2022).Optimization of the Contrast Agent Injection Protocol for Carotid Artery Dynamic Contrast-Enhanced Magnetic Resonance Imaging.JOURNAL OF MAGNETIC RESONANCE IMAGING.
MLA Wang, Yajie,et al."Optimization of the Contrast Agent Injection Protocol for Carotid Artery Dynamic Contrast-Enhanced Magnetic Resonance Imaging".JOURNAL OF MAGNETIC RESONANCE IMAGING (2022).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Wang, Yajie]的文章
[Liu, Xiaoming]的文章
[Wang, Yishi]的文章
百度学术
百度学术中相似的文章
[Wang, Yajie]的文章
[Liu, Xiaoming]的文章
[Wang, Yishi]的文章
必应学术
必应学术中相似的文章
[Wang, Yajie]的文章
[Liu, Xiaoming]的文章
[Wang, Yishi]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。